COMMERCIALTEMPERATURERANGE
IDTCV133
PROGRAMMABLEFLEXPCCLOCKFORP4PROCESSOR
13
Symbol
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
ZO
Current Source Output Impedance(2) VO = VX
3000
—
Ω
VOH3
Output HIGH Voltage
IOH = -1mA
2.4
—
V
VOL3
Output LOW Voltage
IOL = 1mA
—
0.4
V
VHIGH
Voltage HIGH(2)
Statistical measurement on single-ended signal using
660
—
900
mV
VLOW
Voltage LOW(2)
oscilloscope math function
–150
—
150
VOVS
Max Voltage(2)
Measurement on single-ended signal using absolute value
—
1150
mV
VUDS
Min Voltage(2)
–300
—
VCROSS(ABS)
Crossing Voltage (abs)(2)
250
—
550
mV
d - VCROSS
Crossing Voltage (var)(2)
Variation of crossing over all edges
—
140
mV
ppm
Static Error(2,3)
See TPERIOD Min. - Max. values
—
0
ppm
400MHz nominal / -0.5% spread
2.4993
—
2.5133
333.33MHz nominal / -0.5% spread
2.9991
—
3.016
266.66MHz nominal / -0.5% spread
3.7489
—
3.77
TPERIOD
Average Period(3)
200MHz nominal / -0.5% spread
4.9985
—
5.0266
ns
166.66MHz nominal / -0.5% spread
5.9982
—
6.032
133.33MHz nominal / -0.5% spread
7.4978
—
7.54
100MHz nominal / -0.5% spread
9.997
—
10.0533
96MHz nominal
10.4135
—
10.4198
400MHz nominal / -0.5% spread
2.4143
—
333.33MHz nominal / -0.5% spread
2.9141
—
266.66MHz nominal / -0.5% spread
3.6639
—
200MHz nominal / -0.5% spread
4.9135
—
TABSMIN
Absolute Min Period(2,3)
166.66MHz nominal / -0.5% spread
5.9132
—
ns
133.33MHz nominal / -0.5% spread
7.4128
—
100MHz nominal / -0.5% spread
9.912
—
96MHz nominal
10.1635
—
tR
Rise Time(2)
VOL = 0.175V, VOH = 0.525V
175
—
700
ps
tF
Fall Time(2)
VOL = 0.175V, VOH = 0.525V
175
—
700
ps
d-tR
Rise Time Variation(2)
—
125
ps
d-tF
Fall Time Variation(2)
—
125
ps
dT3
Duty Cycle(2)
Measurement from differential waveform
45
—
55
%
ELECTRICAL CHARACTERISTICS - CPU, SRC, AND DOT96 0.7 CURRENT MODE
DIFFERENTIAL PAIR(1)
Following Conditions Apply Unless Otherwise Specified:
Operating Condition: TA = 0°C to +70°C, Supply Voltage: VDD = 3.3V ± 5%; CL = 2pF
NOTES:
1.
SRC clock outputs run only at 100MHz.
2.
This parameter is guaranteed by design, but not 100% production tested.
3.